Short answer: the HC-STAK 35 is a shielded, touch-safe high-voltage interconnection system from TE Connectivity (TE) that carries current between battery, inverter and e-motor in electric, hybrid, plug-in hybrid and fuel-cell vehicles. Rated up to 1000 V DC and carrying up to 400A on 95 mm² conductors at 85 °C, it lets a powertrain raise bus voltage without adding copper, so less energy is wasted as heat and less mass is built into the vehicle. That is why this component release is an efficiency story, not just a distribution story.

What is the HC-STAK 35, and what does it actually do?

It is a "stacked-contact" link rather than a single-crimp connection. Instead of terminating one conductor per circuit, the fork-terminal architecture layers contacts inside one housing, so a designer can scale current capacity up or down without re-laying the high-voltage harness. Mouser Electronics, Inc. has now added the series to its stock, and TE positions it as a future-ready answer to the rising power demand of electrified drivetrains: it routes high-current power among the battery, the inverter and the e-motor while keeping the joint shielded, touch-safe and resistant to vibration, mechanical load and heat.

For engineering and sustainability teams the relevance is narrow but real. Roughly 90% of the energy a battery delivers has to pass through a handful of interconnection points on its way to the wheels. Any contact resistance, shielding gap or thermal derating at those points shows up directly as consumed kilowatt-hours, cooling load and, upstream, as CO₂ per kilometre driven.

Why do up to 400A and 1000 V DC change the energy math?

Conclusion first: voltage is the cheap lever for efficiency; current is the expensive one. For a given power level, doubling bus voltage halves the current, and resistive loss falls with the square of current (P_loss = I²R). Raising the nominal system voltage therefore reduces cable loss, cable mass and cooling demand simultaneously — which is the core reason the market is migrating from 400V toward 800V-class architectures.

Higher voltage is not free, however. Industry guidance on high-voltage harness design notes that an 800V architecture demands stronger insulation ratings, larger creepage and clearance distances and more rigorous component qualification than a 400V one (see wireharnessproduction.com). A device rated up to 1000 V DC gives designers headroom above the 800V bus, so the same interconnect family can serve today's vehicles and tomorrow's higher-voltage platforms without a second tooling cycle.

The scale behind that engineering choice is now hard to ignore. The IEA's Global EV Outlook 2025 records global electric car sales topping 17 million in 2024, up more than 25% year on year and more than one in five of all new cars sold; the agency's later review puts 2025 sales at around 21 million units (https://www.iea.org/reports/global-ev-outlook-2025). When a single component class sits in that many vehicles, a fraction of a percent of interconnect loss is a fleet-level energy number.

Which parameters should you verify before specifying HC-STAK 35?

The headline figures are only usable together with their test conditions. Below, the published values from the master release are set against TE's own product documentation, and the right-hand column is GreencarbonWorld's design reading of each item.

ParameterPublished valueDesign implication
Continuous currentup to 400A with 95 mm² wires at 85 °C (TE also states 400A as the family maximum)The rating is thermal, not absolute: conductor size and ambient temperature must be declared together
Voltage ratingup to 1000 V DCHeadroom above 800V buses; supports common DC-link and future higher-voltage designs
Contact stackingup to 64 layered contact points; TE's flyer states up to 64 per circuit, made from 32 double-ended forksCurrent capacity scales by stacking, so housing count and harness mass stay flat
Cable interface70 or 95 mm² single-core copper conductors with 3.5 mm double-ended fork contacts (TE documentation)Matches typical HV main-power cable sizes, easing reuse across variants
EMI controlshielded, touch-safe form; TE describes 360° shielding for the seriesFull-circumference bonding matters more than the shield label — check the termination method
Protection and fire behaviourmeets IP2XB, IP67 and V0 flammability requirementsIP2XB covers touch protection, IP67 dust and temporary immersion, V0 burn rate — three separate tests
Joint technologylow-resistance fork-style interface with optional ultrasonic weldingWelded joints reduce contact resistance and therefore heat build-up at continuous load
Mechanical dutywithstands vibration, mechanical stress and thermal stressRelevant for AWD, towing and higher curb-weight platforms where the link is load-bearing

HC-STAK 35 or the smaller family members: how do you choose?

Conclusion first: pick by continuous current and cable size, not by voltage, because the voltage rating is common across the family. TE's own product literature shows the family as one scalable platform at 1000 V DC, differentiated mainly by conductor cross-section and stacking depth.

VariantVoltage ratingCable sizesContact stackingTypical fit
HC-STAK 251000 VDC (TE e-card)25, 35 or 50 mm²up to 40 per circuit (TE e-card)Mid-power battery-to-inverter links, smaller packs
HC-STAK 35up to 1000 V DC70 or 95 mm²up to 64 layered contact pointsHigher-output, heavier xEV platforms, AWD and towing duty

Read this way, the "35" designation is not a marketing tier but an ampacity tier. Choosing the smaller variant for a vehicle that only occasionally reaches peak power saves copper; choosing the larger one for a vehicle that runs continuous load protects the efficiency map over the whole duty cycle.

Case read: heavy platforms, AWD and fleet duty cycles

The release explicitly points at platforms with higher curb weight, all-wheel-drive systems or integrated towing capability. Those are exactly the cases where the interconnect becomes the bottleneck, because sustained power, not peak power, drives both current and temperature.

A worked illustration (GreencarbonWorld analysis, using the standard power relation, not vendor data): a drivetrain that must deliver 200 kW continuously draws about 500A on a 400V bus but only about 250A on an 800V bus. The higher-voltage case sits comfortably inside the up to 400A window of a single link, while the lower-voltage case forces either a heavier conductor, a second parallel link or more stacked contacts. In fleet terms this is the difference between a light delivery van architecture and a tow-rated SUV or a battery-electric truck, where sustained low-speed torque and regenerative heating both load the same joints.

The shielding claim is equally practical. A high-current link swinging between battery and inverter is a broadband noise source; with EMI shielding integrated where power moves between those nodes, filter and ferrite content elsewhere in the harness can be trimmed — a cost and mass saving that tends to be discovered late in validation if it is not planned early.

What does it cost, and what are the four most common mistakes?

Published unit pricing and lead time are not disclosed in the release, so the cost discussion below is framed as specification risk rather than price — and GreencarbonWorld recommends treating any interconnect change as a system-level bill of materials decision, not a connector substitution.

  • Treating LV214 and IP67 as one checkbox. LV214 is the German OEM connector qualification specification; sealing grades are tested separately, and supplier guidance is explicit that an LV214-compliant connector is not automatically IP67-rated, nor the reverse (amphenolltw.com). Specify both.
  • Sizing at room temperature. The 400A figure is anchored at 85 °C with a 95 mm² conductor. Re-derate for under-hood or underfloor temperatures instead of assuming the datasheet number travels.
  • Assuming higher voltage has no cost. Insulation class, creepage, clearance, service tools and technician training all step up with the bus. The savings are in copper and loss; the spend is in qualification.
  • Buying outside a traceable channel. For safety-critical HV links, an untraceable batch is a recall exposure. Parts supplied through the authorised channel are described as 100% certified, genuine and fully traceable from manufacturer partners.

How to take HC-STAK 35 from datasheet to build: six action steps

  1. Fix the duty cycle first: continuous kW, peak kW, soak temperature and regeneration profile. Current and temperature, not voltage, set the variant.
  2. Convert those into conductor size — 70 or 95 mm² — and only then into stacking depth, up to 64 contact points, so the housing is sized last.
  3. Write the protection requirements as three separate line items in the specification: touch-safe IP2XB, sealing IP67 and flammability V0, plus any OEM-level qualification such as LV214.
  4. Validate shield termination as an assembly step, not a component attribute; a 360° shield is only effective if bonding continuity survives the production weld.
  5. Prototype the full link with harness, not the connector alone, and measure contact resistance and temperature rise at continuous load.
  6. Lock the supply path early: confirm authorised-channel traceability and pull reference designs and application notes before layout is frozen.

Where to verify stock, documentation and design support

Availability sits with the distributor channel. As a global authorised distributor, Mouser lists the series with stock ready to ship and states that parts supplied through this channel are 100% certified, genuine and fully traceable from manufacturer partners. For design teams, the same channel publishes a technical library — data sheets, supplier-specific reference designs, application notes, design information and engineering tools, hosted around the Technical Resource Center — which is where the derating curves and stacking rules referenced above can be checked against the primary source rather than a summary.

FAQ: green-tech readers ask

Is a 1000 V DC rating the same thing as an 800V vehicle architecture?

No. The rating is the component's dielectric headroom; 800V is the vehicle's operating bus. A device rated up to 1000 V DC can serve an 800V bus with margin for transients and for later voltage increases, but the vehicle still has to be engineered to the higher insulation and clearance requirements that bus imposes.

Why is the current figure always tied to a cable size and a temperature?

Because ampacity is a heat-balance result. The published up to 400A value is defined for 95 mm² wires at 85 °C; change either variable and the safe continuous current changes with it. Comparing two connectors on the amperes number alone is a specification error.

Does a better interconnect measurably lower a vehicle's energy consumption?

It lowers the loss share that sits in the distribution path — contact resistance, shield-induced heating and harness mass — so the effect is real but incremental, and it grows with power level. GreencarbonWorld's reading: the benefit is largest on high-power, high-mass platforms, and smallest on low-power city cars.

Can the platform be used outside passenger EVs?

The series is presented for electric, hybrid, plug-in hybrid and fuel-cell vehicles, i.e. xEV powertrains. Any other high-current, low-voltage-duty application — stationary battery racks, for example — would need its own standard set and independent validation; the automotive ratings do not transfer automatically.

What does touch-safe IP2XB protect against in practice?

It prevents a finger or tool contacting live parts, which is the baseline personnel-safety requirement for service and rescue work on HV systems; sealing (IP67) and burn behaviour (V0) address different failure modes and must be verified separately.

Trend judgment: what to watch next

Three signals matter for 2026 planning. First, interconnect families are consolidating into scalable stacks rather than bespoke terminals, which shortens the gap between a 400V and an 800V variant of the same vehicle. Second, as global electric car sales pass the 20-million-per-year mark reported by the IEA, efficiency gains measured in fractions of a percent are becoming procurement-relevant, not just engineering-relevant. Third, charging and towing duty cycles are pushing continuous current — not peak power — into the specification conversation, which is precisely the parameter this class of link is built around.

Sources referenced

  • TE Connectivity, HC-STAK 35 High-Voltage Interconnection System flyer (fork counts, 360° shielding, 70/95 mm² single-core copper, 3.5 mm double-ended forks): https://www.te.com/content/dam/te-com/documents/automotive/global/hc-stak35-flyer-v3-022526.pdf
  • TE Connectivity, HC-STAK series product page (family ratings at 1000 VDC and 400A at 85 °C): https://www.te.com/en/products/connectors/automotive-connectors/intersection/hc-stak-series-high-voltage-interconnection-system.html
  • TE Connectivity, HC-STAK 25 e-card (25/35/50 mm² wire sizes, up to 40 contacts per circuit): https://www.te.com/content/dam/te-com/documents/automotive/global/e-card-hc-stak-25.pdf
  • IEA, Global EV Outlook 2025 — electric car sales topped 17 million in 2024: https://www.iea.org/reports/global-ev-outlook-2025
  • Amphenol LTW, LV214-compliant connectors explained (LV214 and IP ratings are independent requirements): https://amphenolltw.com/news-events/lv214-compliant-connectors-for-automotive-applications.html
  • Wire Harness Production, EV high-voltage wire harness guide: 400V vs 800V systems (insulation, creepage and clearance implications): https://wireharnessproduction.com/blog/ev-high-voltage-wire-harness-guide
  • ElectroPages, Mouser now stocks TE Connectivity HC-STAK 35: https://www.electropages.com/blog/2026/11/mouser-now-stocks-te-connectivity-hc-stak-35-high-voltage-interconnection-system

Written by Iris Vaughan, GreenTech desk, GreencarbonWorld. For corrections or reader questions, contact info@greencarbonworld.com. GreencarbonWorld does not distribute or resell the components described; all availability statements refer to the distributor named in the source release.

Brand logo

GreencarbonWorld

Green and low-carbon digital solutions for a sustainable, net-zero future.

Carbon MarketsClimate PolicyClean EnergyCorporate ESGGreen TechGlobal BizSight

© 2026 GreencarbonWorld.

Cookie Notice

We use cookies to improve your experience and analyze website traffic. Read our Privacy Policy to learn more.