SemiQ's Gen4 QSiC MOSFETs answer one engineering question: how much converter loss can be removed without changing the die, the package or the production line. Measured against Gen3, the 1200-V part cuts on-resistance by 21% and switching energy by 11%, while the 750-V GP4T009A075 is a voltage class the family has never offered before. This GreenTech case replay sizes what those two numbers are actually worth inside a charging cabinet or an inverter string — and identifies the places where they quietly stop paying.
Case replay by Iris Vaughan · GreencarbonWorld GreenTech desk · data requests: info@greencarbonworld.com
Conclusion first: the improvement is geometric, not physical. SemiQ's Gen4 cell topology shrinks cell pitch by 36% versus previous generations, so more channel width fits in the same silicon area. That is why on-resistance falls while the die does not grow: the 1200-V device keeps a 5×5-mm die, identical to the Gen3 1200-V die it replaces.
| Part | Voltage class | On-resistance | Total switching energy | Die | What is new |
|---|---|---|---|---|---|
| GP4T009A075 | 750-V | 9 mΩ | 871 µJ | not stated in the launch material | first 750-V device of the line-up |
| GP4T011A120 | 1200-V | 11 mΩ | 1491 µJ | 5×5-mm, unchanged from Gen3 | 21% lower on-resistance, 11% lower switching energy |
For a design team, the unchanged die size is the single most useful fact on the list. Thermal resistance from junction to case, current density and board real estate are all anchored to that square, so a Gen3 board can absorb Gen4 silicon without a new mechanical redesign. Coverage of the launch by trade press on 27–28 October 2026 confirms both parts ship in a four-lead TO-247-4L package and as bare die (semiconductor-today.com).
We replay the evaluation as a charger programme would run it, because this is where the loss budget is tightest. A US Department of Energy technology review published in 2019 set the benchmark that still drives the category: 350 kW DC ultra-fast chargers can add roughly 200 miles of range in ten minutes (osti.gov). Recent experimental work keeps the frame current — a 40 kW SiC charger built from two parallel 20 kW modules with a Vienna-rectifier grid stage was validated at module level in a 2026 peer-reviewed comparison of grid-side power quality (frontiersin.org).
Read those two data points together and the device-level arithmetic becomes the bottleneck: high current per switch, high bus voltage, and a loss budget that cooling hardware has to carry away hour after hour. That is precisely the regime where conduction loss — proportional to the square of current times on-resistance — dominates the bill of materials.
Conclusion: the 21% claim is only meaningful at a stated current, and the saving scales with the square of that current. Inverting the published improvement puts the previous Gen3 1200-V part at roughly 14 mΩ on the same basis; conduction loss per device follows.
| RMS current per switch | 1200-V Gen4 at 11 mΩ | implied Gen3 at ~14 mΩ | 750-V Gen4 at 9 mΩ |
|---|---|---|---|
| 10 A | 1.10 W | 1.39 W | 0.90 W |
| 20 A | 4.40 W | 5.57 W | 3.60 W |
| 30 A | 9.90 W | 12.53 W | 8.10 W |
Method note: these are our own calculations from the published anchors (P = I² × R), not vendor measurements. At 20 A they cut to the chase — a high-current leg sheds about 1.2 W per device, and an eight-switch stage recovers roughly 9–10 W. Multiply across a cabinet and those watts stop being trivia, because every watt of device loss must be moved to ambient at a fan or a cold plate.
Conclusion: switching energy figures are a switching-frequency budget, not a loss reading. Multiply the published energy by commutations per second and the ceiling becomes visible.
| Commutations per second | 1200-V at 1491 µJ | 750-V at 871 µJ |
|---|---|---|
| 20 kHz | 29.8 W | 17.4 W |
| 50 kHz | 74.6 W | 43.6 W |
| 100 kHz | 149.1 W | 87.1 W |
Again, our arithmetic. Two readings follow. First, resonant and soft-switching topologies — LLC in chargers, most PV stage designs — never execute the full energy per cycle, so treat the column as a worst case that bounds frequency rather than as an operating loss. Second, at fixed frequency and fixed topology the numbers do behave proportionally: the 11% reduction is a licence to raise switching frequency and shrink the magnetics, or to hold frequency and bank the difference as thermal margin. In practice, inductors and transformers, not semiconductors, are where the volume savings are booked.
Conclusion: a device generation is a budget, not a win. Assume a 20 kW charger module whose device loss totals 600 W, split 40% conduction, 35% switching and 25% other — shares chosen for illustration. Applying the published deltas gives 240 W → 190 W and 210 W → 187 W, so total device loss falls to about 527 W: roughly 73 W saved per module, or about 0.37 percentage points of module efficiency.
For PV and storage owners the same logic lands differently. Efficiency is regulated, auditable value there: China's mandatory national standard GB 47834-2026, released on 27 June 2026 and effective 1 January 2027, brings grid-tied PV inverters into a graded efficiency scheme for the first time (sina.com.cn). Roughly 0.1 percentage point of yield on a plant producing 1,400 MWh a year keeps 1.4 MWh on the feeder, so any device change that reliably moves the weighted curve is worth a re-test.
Conclusion: the new voltage class removes a compromise, not just a loss. SemiQ's own launch wording stresses that, unlike previous generations, the Gen4 line-up now includes a 750-V device (semiq.com). Before that, designers of 380–500 V buses chose between 650-V silicon superjunction devices — which pay a switching-price penalty at high frequency — and a 1200-V SiC MOSFET running far from its optimum.
Where the 750-V, 9 mΩ, 871 µJ combination slots in: bidirectional onboard chargers and V2G stages, battery-storage DC/DC converters, server-rack and intermediate bus conversion, and the PFC leg of mid-power charging modules. The direction of travel is documented — an 800 VDC rack-power architecture, aimed at 1 MW racks with a 2027 window, was published by a leading GPU platform vendor in May 2025 (developer.nvidia.com). Architectures that move DC distribution to the 800 V neighbourhood pull silicon demand toward exactly this class boundary, where derating headroom is worth more than the last milliohm.
Conclusion: reliability claims, not datasheet minima, decide whether a new generation enters production. The Gen4 dies undergo wafer-level gate-oxide burn-in screening at voltages above 800 V for the 750-V part and above 1400 V for the 1200-V part, and both are avalanche-tested to 800 mJ.
Why that is not box-ticking: SiC MOS structures show a higher rate of extrinsic, defect-driven gate-oxide failures than silicon power MOSFETs, which is precisely why on-wafer screening and burn-in are standard practice rather than optional extras — a 2024 study on commercial SiC MOSFETs from Ohio State's power electronics group makes that case with test data (u.osu.edu). The rules are also tightening around the industry: in 2026 JEDEC's wide-bandgap committees published guidance defining short-circuit withstand and accelerated stress protocols for SiC device qualification (powerelectronicsnews.com). An 800 mJ avalanche rating is the practical proof of field tolerance to inductive clamping events — bus-bar inductance, short cables at high di/dt, or a degraded gate resistor — that would otherwise crack a device in year two.
Packaging follows the same logic. The four-lead TO-247-4L variant adds a Kelvin source connection that removes the shared source inductance from the gate-drive loop; manufacturer application notes and design guides report reduced ringing, lower gate oscillation and lower switching energy versus the three-lead package (powermastersemi.com; wolfspeed.com). The trade-off is real: the Kelvin pin must be laid out as a separate, unbroken loop, or the benefit disappears and EMI behaviour changes. Bare die is the alternative when the module is a power film or an embedded substrate — and then the vendor's known-good-die and qualification documentation becomes your responsibility.
Availability is immediate, which shortens evaluation cycles: all four part numbers are released, with the H suffix denoting TO-247-4L and the X suffix bare die — GP4T009A075H, GP4T009A075X, GP4T011A120H, GP4T011A120X.
Electrically and mechanically it starts from the same place — the 1200-V die size is unchanged at 5×5-mm and the package is the same TO-247-4L. Verify gate threshold, drive voltage, derating curves and short-circuit behaviour from the datasheet before assuming a free swap.
Whichever corresponds to your dominant loss term. Conduction-heavy, high-current stages such as charging modules and low-frequency converters read the 21%. High-frequency, resonant or PFC stages where switching energy dominates read the 11%.
Because screening is acceleration, not operation. Stressing the gate oxide beyond the rated class pushes weak, defect-driven sites to fail on the wafer rather than in the field; the 1200-V dies get the same treatment above 1400 V.
Three places: less wasted energy per kWh delivered, smaller cooling hardware and thus lower material intensity, and longer asset life once the screened devices are combined with an 800 mJ avalanche rating.
All loss, wattage and annual-energy figures in this replay are GreencarbonWorld calculations built on the published device anchors, with assumptions stated in the text. They are screening estimates for prioritising tests, not measured efficiency and not vendor representations.
Written by Iris Vaughan for the GreencarbonWorld GreenTech desk. Request the calculation spreadsheet or flag a correction: info@greencarbonworld.com.